PALD1000 DATA CENTER LOAD
Series:
Key facilities in a data center include power distribution and air conditioning systems. Comprehensive testing involves load testing these key facilities. IT equipment is installed gradually after the data center is put into use. That is, during construction acceptance, there is no IT load in the data center, resulting in many problems with key facilities not being exposed. Therefore, simulated loads have emerged. Simulated loads mimic the actual operation and heat generation of IT equipment, ensuring the effective operation of the data center's supporting power distribution system (including UPS system), air conditioning and fresh air system, lightning protection grounding system, monitoring system, etc. Testing allows for the timely discovery and resolution of problems, preventing safety hazards.

Details
Product Features
Dummy load verification testing, as a comprehensive check and test before the commissioning of a new data center, has been increasingly recognized and supported by industry professionals. It is an indispensable key project phase in new data center projects. The introduction of this phase plays a very important role in project, operation, and data center lifecycle management. It can eliminate hidden dangers in advance, establish operation procedures, and conduct operational drills. It is also the final guarantee for the overall project delivery quality. At this stage, hidden dangers buried in design, construction, equipment, etc., can be rectified at the lowest cost, thereby avoiding systematic risks of the project.
Product Applications
Data center cooling system acceptance / Data center airflow environment acceptance report / Data center design index verification / Data center power system acceptance
Product Specifications
AC/DC Rack-Mount Dummy Load | |
Model | PALD-1004 Data Center Test AC Dummy Load |
Main technical indicators of the load box, parameters can be customized according to customer needs | |
Rated Voltage | Ue=220V AC/DC, AC 220Vac, DC 270V |
Rated Power | 4.5kW |
Maximum Current | 20.4A |
Minimum Step | 0.5KW |
Accuracy | 3% |
Control Method | Manual |
Panel Layout | Power switch, power adjustment switch, buzzer |
Power Socket | C14 Power Socket |
Load Mode | Constant Resistance |
Protection Function (Optional) | Short circuit protection, over temperature protection, fan failure protection |
Heat Dissipation Method | Air Cooling |
Working Power Supply | Input Provided |
Installation Method | Complies with 19-inch standard rack mounting specifications |
Operating Environment | -10℃~55℃ |
Dimensions | 4U |
Equipment Weight | 15KG |
Appearance Color | Black |
◆Please contact the company's business department for special specifications. The company accepts customized orders according to user needs.