ALB series AC loads include single-phase AC loads, three-phase AC loads, RL impedance loads, RLC impedance capacitive loads, and RCD non-linear loads. Products are widely used in daily maintenance testing, project acceptance, factory inspection testing, and product aging of various switching power supplies, medium-frequency aviation power supplies, and inverters. They can simulate the starting characteristics, stability characteristics, transient characteristics, and output parameter testing processes of purely resistive, inductive, capacitive, and mixed loads, and detect the performance of AC power supplies when connected to different loads. Power input uses optimized segmented power input to adapt to different loads and power factors.

Product Inquiry
Image Name

Details

  Product Features


◆ Made with stainless steel alloy resistors and high-quality inductors and capacitors

◆ Discharge power can be set by key combination according to power detection requirements.

◆ Detects the working efficiency, maximum output power under full load, and load capacity of various power generation and discharge equipment.

◆ Simulates various complex working environments, sudden increase and decrease of power, and detects the actual load capacity and efficiency of discharge equipment.

◆ The use of precise high-precision load materials can truly simulate the load capacity and load micro-change adaptability of the actual load.

◆ Emergency stop and temperature protection, overload, short circuit, and overtemperature equipment automatic shutdown.

◆ Upper and lower limit voltage setting, automatically reduces to the range voltage point according to energy (limited control machine)

◆ AC/DC integrated machine can be customized for users, which can be used for AC and DC (customized)

◆ Temperature protection setting, temperature 0~100° can be set, and real-time temperature is monitored.

◆ Programmable interface, 0~30 groups of power and current can be set arbitrarily, the minimum execution operation time is 1ms, and it can be cycled 999999 times (limited control machine)

◆ The minimum resolution of the load is 1W, which can accurately simulate the on/off capability of power generation or products.

◆ Measurement data can be uploaded to a computer to realize the function of recording and storing data during the detection process (limited control machine)

◆ It has two operation modes: panel operation or remote control (limited control machine)

◆ It has over-temperature protection function, temperature setting and temperature monitoring.

◆ Customizable power factor 0.3~1 adjustable load

◆ Applied to the precise testing sites of generators, UPS, switches, fuses, electrical accessories, transformers, temperature rise tests, low-voltage electrical appliances' factory inspection, production debugging, simulation of harsh load environments, scientific research and development, military industry, etc.

◆ Button control or switch switching (touch screen control including RS232 communication interface)

◆ Can measure voltage, current, power, reactive power, active power, apparent power, and power factor.

◆ Resistive, inductive, and capacitive loads, as well as adjustable power factor test loads, can be customized according to the actual needs of users.

 

  Product Applications


AC power supply / AC generator / UPS power supply / inverter / charging pile / switch components and other load testing occasions

 

  Product Specifications


Product NameAC Single-Phase Load BoxMedium Frequency Load Box
Model (Manual Adjustment)ALB-DR5ALB-DR10ALB-DR30ALB-DR10ZALB-DR30Z
Model (Programmable Control)PLB-DR5PLB-DR10PLB-DR30PLB-DR10ZPLB-SR30Z

Main Technical Indicators of Load Box

Default load nature: R, LC please refer to IP-RLC selection

Maximum Discharge Power5KW10KW30KW10KW30KW
Discharge Voltage RangeAC 220VAC 220VAC 220VAC 115VAC 200V/115V Three-Phase
Frequency50HZ/60HZ50HZ/60HZ50HZ/60HZ400HZ400HZ
Voltage Accuracy0.50%0.50%0.50%0.50%0.50%
Voltage Resolution0.1V0.1V0.1V0.1V0.1V
Current Measurement Range0-22A0-50A0-140A0-86A0-86A
Power Measurement Range0.1-5kw0-10kw0-30kw0-10kw0-10kw
Adjustment Accuracy0.1KW0.1KW0.1KW0.1KW0.1KW
Power SupplyAC 220V/50HZAC 220V/50HZAC 220V/50HZAC 220V/50HZAC 220V/50HZ
Display MethodLED Digital MeterLED Digital MeterLED Digital MeterLED Digital MeterLED Digital Meter
Protection DeviceOvervoltage, high temperature alarm, fan failure protectionOvervoltage, high temperature alarm, fan failure protectionOvervoltage, high temperature alarm, fan failure protectionOvervoltage, high temperature alarm, fan failure protectionOvervoltage, high temperature alarm, fan failure protection
Heat Dissipation MethodForced Air CoolingForced Air CoolingForced Air CoolingForced Air CoolingForced Air Cooling
Dimensions430*550*178mm480*650*600mm600*900*1000mm480*650*600mm600*900*1000mm
Optional FunctionsNANA

 

Remote Computer Monitoring

Touch Screen Control

 

NA

Remote Computer Monitoring

Touch Screen Control

Programmable Control Function

Uses touch screen + PLC control; programmable group number 30 groups (setting current or power and running time)

External Communication USB/232/485/CAN

OtherVoltage and frequency can be customized according to customer requirements; resistive, inductive, and capacitive loads can be customized.

◆ Our company's product specifications are constantly being developed and improved. Changes will be made without further notice.

◆ Please contact our technical staff for inquiries and technical support.

◆ Please contact the company's business department for special specifications. The company accepts special customization according to user needs.

Image Name

Related Products

Online Consultation


Please fill in the correct contact information, our customer service staff will contact you as soon as possible!

%{tishi_zhanwei}%