PRODUCT

Product
-
-
Communication inverter variable frequency power supply


ALB-SR AC THREE-PHASE SERIES
Series:
ALB series AC loads include single-phase AC loads, three-phase AC loads, RL impedance loads, RLC impedance capacitive loads, and RCD non-linear loads. Products are widely used in daily maintenance testing, project acceptance, factory inspection testing, and product aging of various switching power supplies, medium-frequency aviation power supplies, and inverters. They can simulate the starting characteristics, stability characteristics, transient characteristics, and output parameter testing processes of purely resistive, inductive, capacitive, and mixed loads, and detect the performance of AC power supplies when connected to different loads. Power input uses optimized segmented power input to adapt to different loads and power factors.

Details
Product Features
◆ Made with stainless steel alloy resistors and high-quality inductors and capacitors
◆ Discharge power can be set by key combination according to power detection requirements.
◆ Detects the working efficiency, maximum output power under full load, and load capacity of various power generation and discharge equipment.
◆ Simulates various complex working environments, sudden increase and decrease of power, and detects the actual load capacity and efficiency of discharge equipment.
◆ The use of precise high-precision load materials can truly simulate the load capacity and load micro-change adaptability of the actual load.
◆ Emergency stop and temperature protection, overload, short circuit, and overtemperature equipment automatic shutdown.
◆ Upper and lower limit voltage setting, automatically reduces to the range voltage point according to energy (limited control machine)
◆ AC/DC integrated machine can be customized for users, which can be used for AC and DC (customized)
◆ Temperature protection setting, temperature 0~100° can be set, and real-time temperature is monitored.
◆ Programmable interface, 0~30 groups of power and current can be set arbitrarily, the minimum execution operation time is 1ms, and it can be cycled 999999 times (limited control machine)
◆ The minimum resolution of the load is 1W, which can accurately simulate the on/off capability of power generation or products.
◆ Measurement data can be uploaded to a computer, and the process data of the detection process can be recorded and stored (limited control machine)
◆ Two operation modes: panel operation or remote control (limited control machine)
◆ Overtemperature protection function, temperature setting and temperature monitoring
◆ Customizable power factor 0.3~1 adjustable load
◆ Applied to the factory inspection, production debugging, simulation of harsh load environments, scientific research and development, military industry, and other precise testing sites of generators, UPS, switches, fuses, electrical accessories, transformers, temperature rise tests, and low-voltage electrical appliances
◆ Button control or switch switching (touch screen control with RS232 communication interface)
◆ Measures voltage, current, power, reactive power, active power, apparent power, and power factor
◆ Resistive, inductive, and capacitive loads can be customized according to the actual needs of users; and the power factor can be adjusted for testing loads
Product Applications
Load testing occasions for AC power supply/AC generator/UPS power supply/inverter/charging pile/switch components, etc.
Product Specifications
ALB-S Three-Phase AC Series Load | |||||
Product Model | ALB-SR5 | ALB-SR10 | ALB-SR20 | ALB-SR30 | ALB-SR50 |
Test Voltage | AC380V | AC380V | AC380V | AC380V | AC380V |
Load Nature | Precision R Load (Constant Resistance Value) Voltage Rated Voltage Current Decrease Proportionally | ||||
Test Power | 0.1K-5K | 0.1K-10K | 0.1K-20K | 0.1K-30K | 0.1K-50K |
Minimum Step | 0.1K | 0.1K | 0.1K | 0.1K | 1K |
Control Method | Manual Control | Manual Control | Manual Control | Manual Control | Manual Control |
Voltage Test Accuracy | 0.5% Standard | ||||
Current Test Accuracy | 0.5% Standard | ||||
Frequency Power Accuracy | 0.5% | ||||
Voltage Current Resolution | V=0.1 I=0.01 | I=0.01 | |||
R Error | 2% | 2% | 2% | 2% | 2% |
Working Mode | Long-Term Operation | Long-Term Operation | Long-Term Operation | Long-Term Operation | Long-Term Operation |
Protection Level | IP20 | ||||
Withstand Voltage Level | 1600V1min | ||||
Output Method | Terminal Block | ||||
Airflow Method | Bottom Inlet, Top Outlet | ||||
Service Life | No less than 10 years with standard operation | ||||
Cooling Method | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling |
Protection Function | Overtemperature Alarm | Overtemperature Alarm | Overtemperature Alarm | Overtemperature Alarm | Overtemperature Alarm |
Overcurrent Short Circuit | Overcurrent Short Circuit | Overcurrent Short Circuit | Overcurrent Short Circuit | Overcurrent Short Circuit | |
Short Circuit Protection | Short Circuit Protection | Short Circuit Protection | Short Circuit Protection | Short Circuit Protection | |
Meter Display | Voltage Current | Voltage Current | Voltage Current | Voltage Current | Voltage Current Frequency Power |
Auxiliary Voltage | AC220V 50HZ | AC220V 50HZ | AC220V 50HZ | AC220V 50HZ | AC220V 50HZ |
Dimensions L*W*H | 750*480*700 | 800*480*820 | 900*650*1000 | 900*650*1300 | |
Special Features | Non-standard specifications can be customized according to customer requirements |
See the table below:
Product Model | ALB-SR100 | ALB-SR200 | ALB-SR300 | ALB-SR400 | ALB-SR500 | |
Test Voltage | AC380V | AC380V | AC380V | AC380V | AC380V | |
Load Nature | Precision R Load (Constant Resistance Value) Voltage Rated Voltage Current Decrease Proportionally | |||||
Test Voltage | The above specifications are all our company's conventional models. Please call for special voltages. The default for ascending models is AC380V. | |||||
Test Power | 1K-100K | 1K-200K | 1K-300K | 1K-400K | 1K-500K | |
Minimum Step | 1K | 1K | 1K | 1K | 1K | |
Control Method | Manual Control | Manual Control | Manual Control | Manual Control | Manual Control | |
Voltage Test Accuracy | 0.5% Standard | |||||
Current Test Accuracy | 0.5% Standard | |||||
Frequency Power Accuracy | 0.5% | |||||
Voltage Current Resolution | V=0.1 I=0.1 | |||||
R Error | 2% | 2% | 2% | 2% | 2% | |
Working Mode | Long-Term Operation | Long-Term Operation | Long-Term Operation | Long-Term Operation | Long-Term Operation | |
Protection Level | IP20 | |||||
Withstand Voltage Level | 1600V1min | |||||
Output Method | Terminal Block | |||||
Airflow Method | Left Inlet, Right Outlet | |||||
Service Life | No less than 10 years with standard operation | |||||
Cooling Method | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling | |
Protection Function | Overtemperature Alarm | Overtemperature Alarm | Overtemperature Alarm | Overtemperature Alarm | Overtemperature Alarm | |
Overcurrent Short Circuit | Overcurrent Short Circuit | Overcurrent Short Circuit | Overcurrent Short Circuit | Overcurrent Short Circuit | ||
Short Circuit Protection | Short Circuit Protection | Short Circuit Protection | Short Circuit Protection | Short Circuit Protection | ||
Meter Display | Voltage, Current, Frequency, Power, Active Power, Reactive Power, Power Factor | |||||
Auxiliary Voltage | AC220V/380V 50HZ | |||||
Dimensions L*W*H | 950*940*1600 | 950*1200*1600 | 1450*1100*1700 | 1750*1350*1700 | ||
Special Features | Non-standard specifications can be customized according to customer requirements |
◆ You can contact our technical staff for inquiries and technical support.
◆ Our company's product specifications are constantly being developed and improved. Changes will be made without further notice.
◆ Please call the company's business department for special specifications. The company accepts custom orders based on user needs.

Related Products